Gas alarm GA 607
Operation and safety notes
with sensor for liquid gas (propane, butane)
and town gas/natural gas (methane)
Operation and safety notes Page 5
T 72
IB_GA607_UK_IRL_Cover.indd 1-3IB_GA607_UK_IRL_Cover.indd 1-3 20.09.2005 12:13:55 Uhr20.09.2005 12:13:55 Uhr
Vista de página 0
1 2 3 4 5 6 ... 13 14

Resumo do Conteúdo

Página 1 - Gas alarm GA 607

DexaplanGas alarm GA 607Operation and safety noteswith sensor for liquid gas (propane, butane)and town gas/natural gas (methane) Operation and safety

Página 2 - 15-30 cm

12Installation Danger: make sure that the gas alarm is not live during installation.앩 Remove the mounting fi xture 햸 from the rear side of the casi

Página 3

13The alarm continues until the gas concentra-tion falls back to below the pre-set sensitivity level.Follow the instructions on to how to respond in t

Página 4 - Features

14responded.The alarm continues until the gas con-centration falls back to below the pre-set sensitivity level.Maintenance and cleaning Danger: make

Página 5 -  Danger!

15the warranty, please contact the service offi ce for your country. This is the only way to ensure that your device can be sent in free of charge. Thi

Página 6

Gas alarm GA 607IMPORTANT INFORMATION FOLLOWING AN ALARMIf the alarm indicates a gas leak or you can smell gas: DANGER OF EXPLOSION! • Extinguish all

Página 7

15-30 cmmax. 6mmax. 4m15-30 cmPossible source of escaping gas(consumer appliance)Position for methane(town gas/natural gas): highPosition for liquid g

Página 8 - Initial operation

Introduction ... Page 6Proper use ...

Página 9 - Power supply

6IntroductionPlease read these operating instructions thor-oughly and carefully. They are part of this product and contain important instructions rela

Página 10 - Operation

햸 Mounting fi xture햹 12 V DC terminal screws햺 Cable guide햻 Side and lower sensor openingsTechnical dataGas alarm:Power supply: 12 Volt DC (±10%) ma

Página 11 - Fault Cause Remedy

8• Do not leave children unsupervised with the device. Danger to life and risk of injury.• Do not damage any gas, electricity or telecommunication

Página 12

9Before connecting a 12 V DC mains adapter to the mains, make sure that the mains current is 230 V ~ 50 Hz and equipped with a max. 16 amp fuse in acc

Página 13 - Declaration of conformity

10Initial operationPreparation and materials required:The stated materials are not included in the delivery scope. The information provided here is no

Página 14 -  DANGER OF EXPLOSION!

11below –10° C or rise above +50°C or in which air humidity can rise above 95%.앩 Areas in which dust or dirt can clog the sensor.앩 Any position

Comentários a estes Manuais